Product Details
  • Simply set the desired temperature in increments of 0.1, wait for the calibrator to attain equilibrium, point the infrared thermometer at the target and compare measurements
  • For calibrating non-contact temperature instruments (infrared thermometers, pyrometers and thermal imagers)
  • Wide aperture compensates for optical infrared thermometer variations
Go to full description & specifications


1395
1395
https://www.staples-3p.com/s7/is/image/Staples/m004563263
00800837000217
Reed Instruments
REED BX-500 Calibrator, Infrared Thermometer 122/932degF, 50/500degC
Product Description

The Bx -500 is capable of calibrating non-contact infrared thermometers up to 932degree f (500degree C).

  • Simply set the desired temperature in increments of 0.1, wait for the calibrator to attain equilibrium, point the infrared thermometer at the target and compare measurements
  • For calibrating non-contact temperature instruments (infrared thermometers, pyrometers and thermal imagers)
  • Wide aperture compensates for optical infrared thermometer variations
  • Contact RTD reference well located directly behind the blackbody target to assure accurate results
  • Wide field of view to compensate for optical variations in individual infrared thermometers
  • 4.5"H x 9.25"W x 7"D
  • Black
  • Temperature controlled black-body target with a diameter of 2.25 inches (57mm)
  • Simply set the desired temperature in increments of 0.1degree , wait for the calibrator to attain equilibrium, point the infrared thermometer at the target and measure radiated energy
  • Contact RTD reference well is located directly behind the blackbody target to assure even higher accuracies of + or -0.1degree C
  • Temperature range of 122.0 to 932.0degree f (50.0 to 500.0degree C)
  • Resolution of 0.1degree f (0.1degree C)
  • Accuracy of + or -1.6degree f (+ or -0.8degree C) at Greater than or equal to 212degree f (100degree C), + or -3.2degree f (+ or -1.6degree C) at 212 to 392degree f (100 to Greater than or equal to 200degree C) or + or -5.6degree f (+ or -2.8degree C) at 392 to Greater than or equal to 932degree f (200 to Greater than or equal to 500degree C)
  • Stability of + or -0.2degree f (+ or -0.1degree C) at Greater than or equal to 212degree f (100degree C), + or -0.4degree f (+ or -0.2degree C) at 212 to 662degree f (100 to Greater than or equal to 350degree C) or + or -0.8degree f (+ or -0.4degree C) at 662 to Greater than or equal to 932degree f (350 to Greater than or equal to 500degree C)
  • 45minutes cooling time to 122degree f (100degree C)
  • 40 minutes heating time to maximum temperature